Skip to content

Smart PV field contract and evidence matrix

This is a code-verified mapping, not an authenticated GraphQL introspection result. The fields below are selected by the checked-in queries on main and mapped by the library's typed models. Their Python types and null handling are shown, not provider-declared GraphQL scalar types or ! (non-null) schema guarantees. The existing sanitized fixtures and issue #244's redacted observation support only the indicated values; synthetic test fixtures are not provider schema evidence.

On 2026-11-11, authorized read-only diagnostics reported that __typename succeeded but __schema returned GRAPHQL_VALIDATION_ERROR. This does not prove why introspection was rejected. No provider SDL or comprehensive official Smart PV type definition was available. No additional provider field was independently confirmed; merged PR #246 did not select speculative fields. The scope of issue #244 is limited to independently verifiable, relevant fields, not an exhaustive inventory of the external provider schema.

Inventory — FrankEnergie.smart_pv_systems()

All paths are relative to data.smartPvSystems[].

GraphQL field Python attribute Python type Nullable in model Evidence
id SmartPvSystem.id str No Query, model, fixture
brand brand str No Query, model, fixture
connectionEAN connection_ean str No Query, model, fixture
createdAt created_at datetime No Query, model, fixture
deletedAt deleted_at datetime \| None Yes Query, model, null fixture
displayName display_name str \| None Yes Query, model, fixture
externalReference external_reference str No Query, model, fixture
inverterSerialNumbers inverter_serial_numbers list[str] Null maps to [] Query, model, fixture and regression
model model str \| None Yes Query, model, fixture
onboardingStatus onboarding_status SmartPvOnboardingStatus No Query, model, fixture
provider provider str No Query, model, fixture
steeringStatus steering_status SmartPvSteeringStatus No Query, model, fixture and redacted observation
updatedAt updated_at datetime No Query, model, fixture
SmartPvSystemPanelGroups panel_groups list[SmartPvSystemPanelGroup] No Query, model, new synthetic fixture

Panel groups — data.smartPvSystems[].SmartPvSystemPanelGroups[]

GraphQL field Python attribute Python type Nullable in model Evidence
id SmartPvSystemPanelGroup.id str No Query, model, new synthetic fixture
position position int \| None Yes Query, model, new synthetic fixture
azimuth azimuth int \| None Yes Query, model, new synthetic fixture
tilt tilt int \| None Yes Query, model, new synthetic fixture
capacityKwp capacity_kwp float \| None Yes Query, model, new synthetic fixture
annualKwh annual_kwh int \| None Yes Query, model, new synthetic fixture
panelCount panel_count int \| None Yes Query, model, new synthetic fixture
installationDate installation_date datetime \| None Yes Query, model, new synthetic fixture

Summary — FrankEnergie.smart_pv_system_summary(device_id)

All paths are relative to data.smartPvSystemSummary.

GraphQL field Python attribute Python type Nullable in model Evidence
operationalStatus SmartPvSystemSummary.operational_status SmartPvOperationalStatus No Query, model, fixture and redacted observation
operationalStatusTimestamp operational_status_timestamp datetime \| None Yes Query, model, fixture
steeringStatus steering_status SmartPvSteeringStatus No Query, model, fixture and redacted observation
totalBonus total_bonus float \| None Yes Query, model, fixture and redacted observation
totalResult total_result float \| None Yes Query, model, expanded synthetic fixture and redacted observation

These are 14 inventory fields, 8 nested fields, and 5 summary fields (27 query-selected fields). No untyped raw-response passthrough is used. All selected fields are required to appear in successful responses, even when the documented Python type accepts an explicit null. Nullability above is a library contract and is not claimed to match the remote schema.

Verification status and unsupported assumptions

  • Implemented baseline: all 27 query-selected paths already map to typed Python attributes on main. Merged PR #246 expanded deterministic tests and documented those mappings; no speculative query selections were added.
  • Verified missing provider fields: none established by available evidence. A new field may only be introduced after an authorized source establishes its exact GraphQL type, path, nullability and actual response semantics.
  • Unverified candidates: additional system metadata, panel-group attributes, inverter telemetry, performance/production measurements, unit/currency of totals, and other historical/periodic summary fields. These are categories of investigation, not confirmed field names or endpoint capabilities.
  • Status semantics: steeringStatus=INACTIVE does not prove device disconnection; operationalStatus=ON does not prove actual production. totalBonus and totalResult retain the provider values without inferring units or accounting periods.
  • Safety: a feature-disabled GraphQL error or malformed inventory is not a verified empty inventory; see issue #243. No live private records, EANs or serials were used in this audit.

Acceptance boundary for issue #244

Completion means that all independently verifiable, relevant Smart PV fields within the supported read-only operations have documented evidence, are selected in the corresponding GraphQL queries, and are exposed through typed models with compatible behavior and regression tests. This matrix separates:

  • Already implemented: the 27 selected paths listed above.
  • Independently confirmed but missing: none identified from available evidence.
  • Unverified candidates: the categories listed above; their existence, schema types, nullability, units and response semantics remain unconfirmed.

A provider SDL or successful __schema introspection is not a prerequisite for closing #244 under its revised criteria, provided the bounded mapping, quality checks and mandatory human review have been verified. Closing the issue must not be described as proof that all fields supported by the provider have been discovered.

If additional fields are independently confirmed later, document their exact source, GraphQL path, types and semantics, and track any required model/query changes as separate follow-up work. Do not guess unsupported field names.