Skip to content

Smart PV inventory and GraphQL status

The asynchronous client exposes the read-only FrankEnergie.smart_pv_systems() and FrankEnergie.smart_pv_system_summary(device_id) methods.

The Smart PV field matrix documents all 27 currently selected fields, their typed model mappings, and the evidence boundary. A read-only __typename check succeeded on 2026-11-11, but __schema was rejected with a GraphQL validation error. This does not establish why introspection failed or which unqueried fields might exist. Under issue #244, acceptance covers independently verifiable fields, not the complete provider schema. A provider schema export is not required for issue closure.

Inventory: smart_pv_systems()

The Smart PV inventory is a SmartPvSystems model with a systems list. A verified empty inventory is returned only when the provider successfully returns an explicitly empty list, without GraphQL errors:

{"data": {"smartPvSystems": []}}

A user-supplied, real GraphQL response when Smart Feed-In is not enabled is:

{
  "data": null,
  "errors": [
    {
      "message": "user-error:smart-feed-in-not-enabled",
      "path": ["smartPvSystems"]
    }
  ]
}

For this exact known response, smart_pv_systems() raises SmartFeedInNotEnabledException, a subtype of RequestException, rather than producing a verified empty inventory. The exception does not establish whether physical solar panels exist, or whether previously registered hardware was disconnected.

Missing, partial, malformed or error-bearing inventories raise RequestException rather than being silently treated as absent. Returned systems require complete queried records and unique nonblank string IDs. Nested panel groups also require valid unique IDs. Malformed non-null panel-group numeric values and dates are rejected rather than silently interpreted as missing. Valid null optional values and supported numeric-string representations remain accepted. A null or non-string connectionEAN is invalid; deletedAt may be null but must be a valid date string when present. A null inverter-serial-number list retains its supported empty-list model representation.

Summary: smart_pv_system_summary(device_id)

A summary independently contains operational_status, operational_status_timestamp, steering_status, total_bonus and total_result. A provider-reported operational_status=ON is not a production measurement; steering_status=INACTIVE does not establish disconnection. UTC timestamps remain timezone-aware.

Downstream applications

A consumer must distinguish a successful empty PV inventory from SmartFeedInNotEnabledException and other RequestException results. In particular, Home Assistant's stale-device Repairs must not count feature-disabled or malformed responses as verified absence.

Related: python-frank-energie #243 and Home Assistant #455.